AMX nxd-700vi Intercom System User Manual


 
Configuring Communication
41
NXD-700Vi 7" Modero® Wall/Flush Mount Touch Panel with Intercom
Configuring Communication
Overview
Communication between the Modero panel and the Master is done using either USB or ETHERNET (DHCP
or Static IP). Ethernet communication can be achieved through either a direct connection (Ethernet) or
through the use of the optional NXA-WC802.11GCF wireless CF card.
Modero Setup and System Settings
AMX Modero panels feature on-board Setup pages. Use the options in the Setup pages to access panel
information and make various configuration changes.
Accessing the Setup and Protected Setup Pages
1.
Press the grey Front Setup Access button for 3 seconds to open the Setup page (FIG. 24).
2. Press the Protected Setup button. This invokes a keypad for entry of the password to allow access to the
Protected Setup page. Enter 1988 (the default password), and press Done to proceed.
Before commencing, verify you are using the latest NetLinx Master and Modero panel
firmware. Verify you are using the latest versions of AMX’s NetLinx Studio and
TPDesign4 programs.
USB input devices must be plugged into the rear or side USB connectors before the
G4 panel is powered-up. The panel will not detect a USB connection of this type until
after the unit cycles power.
FIG. 24 Setup page
Battery Base button doesn’t appear
until NXT is connected to a BASE/1
Connection Status
Red Connection Status icon -
Green Connection Status icon -
indicates no connection
indicates communication
to a Master
to a Master
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.