Configuring the conference system
64
To manually initialize certain conference units with the access point:
̈ Switch on all conference units that you want to use in your conference
system (see
page 31).
̈ In the “Init Control” box, select the “Manual” option button.
̈ Click “Clear Init List”.
The existing “Units in Init List” list will be deleted (where applies).
̈ Click “Start init”.
The initialization process starts. All conference units that are
operational show a microphone LED
0 flashing green and red and a
signal light ring
2 flashing red.
̈ Press the microphone key A of the conference unit that you want to
initialize.
The microphone LED 0 and the signal light ring 2 go off. The
conference unit is initialized and listed in the “Units in Init List”. The
conference units are assigned microphone numbers in the order of
initialization. These microphone numbers allow you to clearly identify
the conference units.
̈ Repeat these steps for all conference units that you want to initialize.
̈ Click “Save and Stop Init”.
The initialization process is stopped. The initialized conference units
are saved in the “Units in Init List”. The microphone LED
0 and the
signal light ring
2 go off.
When the conference system is switched on the next time, only the
conference units listed in the “Units in Init List” will be used for
conferencing.
V
2
:
:
C CV D DV
2
:
:
A
C CV D DV
Make sure that no conference units are initialized unintentionally.
̈ Use the “Unit Monitoring” function to check that only “wanted”
conference units are initialized (see
page 62).
In order to increase the safety of your conference system, you can
individually adjust the encryption of the radio communication (
see
“Eavesdropping protection and encryption – “Encryption”” on
page 67).