Configuring the conference system
58
̈ In the “Maximum number of active microphones” box, select the
desired option button.
The number of simultaneously active microphones can be between “1”
and “8”.
̈ Click “Save settings”.
The setting is saved. The speaker limit is set to the selected value.
Setting the conference mode
The WiCOS conference system offers different conference modes, allowing
you to tailor a conference to your needs.
̈ In the main navigation, click “Conference management”.
The “General Conference Settings” overview screen appears.
̈ In the “Microphone Mode” box, select the desired option button.
Refer to the table below for more information on the individual
conference modes.
̈ Click “Save settings”.
The setting is saved. The conference system is set to the selected
conference mode.
Regardless of the conference mode and speaker limit set, the
following applies:
• With a chairman unity you can take the floor immediately
without first having to be assigned the “speaking right”.
• Active chairman units are not counted against the speaker limit.
Conference mode Speaker limit
By pressing the microphone
key
A ...
Chairman unit
Cancellation of a
request to speak
“With request“
1 to 8
... you make a request to speak
and join the request-to-speak
list. You can only take the floor
after you have been assigned
the “speaking right”.
required –
assigns the
“speaking right”
possible
“With request no
clear“
not possible