NEC ND-70919 IP Phone User Manual


 
CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-BRI Programming
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 77
DESCRIPTION DATA
(1)
(2)
YY=05 Release signal from distant
office
00-63: B channel/D channel Trunk
Route No.
1 : Release signal arrives
NOTE 2
(1)
(2)
YY=09 Incoming Connection Signaling
00-63: Trunk Route No.
08: ISDN Indial
(1)
(2)
YY=11 Toll Restriction
00-63: B channel Trunk Route No.
0 : Provided
NOTE 1
3 : Not provided
(1)
(2)
YY=12
Number of digit to be received on DID
00-63: B channel Trunk Route No.
0 : 1 digit
NOTE 1
1 : 2 digits
2 : 3 digits
3 : 4 digits
(1)
(2)
YY=14 SMDR for outgoing call
00-63: B channel Trunk Route No.
0 : Not provided
1 : Provided
NOTE 1
(1)
(2)
YY=15 Kind of Call Termination Indica-
tor Key/Lamp on ATT
00-63: B channel Trunk Route No.
00-07: C.O. Incoming 0-7
NOTE 1
(1)
(2)
YY=16
Hooking Signal Sending to outside
00-63: B channel Trunk Route No.
0: Not sending
NOTE 1
(1)
(2)
YY=18 Digit conversion on DID call
00-63: B channel Trunk Route No.
0 : Provided
NOTE 1
1 : Not provided
CM35
B
C