NEC ND-70919 IP Phone User Manual


 
NEAX2000 IVS
2
ISDN System Manual
Page 188 ND-70919 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-2ILCA (ILC)
Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and , the setting of the switch varies with the system concerned.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SW1
(Piano Key SW)
1 Always set to OFF.
2 Always set to OFF.
3 Always set to OFF.
4 Always set to OFF.
SW0
(Piano Key SW)
1
No. 0
Circuit
(Receiving)
Terminating register is
provided.
OFF
Terminating register is
not provided.
2
No. 0
Circuit
(Sending)
Terminating register is
provided.
OFF
Terminating register is
not provided.
3
No. 1
Circuit
(Receiving)
Terminating register is
provided.
OFF
Terminating register is
not provided.
4
No. 1
Circuit
(Sending)
Terminating register is
provided.
OFF
Terminating register is
not provided.
4
3
2
1
OFF
ON
OFF
OFF
OFF
OFF
4
3
2
1
OFF
ON
ON
ON
ON
ON