CHAPTER 4 CIRCUIT CARD INFORMATION
PN-SC03 (ICH)
NEAX2000 IVS
2
ISDN System Manual
ND-70919 (E), Issue 1.0
Page 181
Switch Settings
The figure in the SWITCH NAME column and the position in in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and , the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENSE
(Rotary SW)
NOTE 1
4-F Set the switch to match the AP Number (04-15) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2
UP For make-busy
For normal operation
F
4
AP No.
04 05 06 07 08 09 10 11 12 13 14 15
SW No.
456789ABCDEF
ON
DOWN