CHAPTER 4 CIRCUIT CARD INFORMATION
PN-30DTC-A (DTI)
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SENS
(Rotary SW)
NOTE 1
4-F Set the switch to match the AP Number (04-31) to
be set by CM05.
0-3 Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
(Continued)
F
4
AP No.
SW-8: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW-8: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
456789ABCDEF
ON
DOWN