NEC ND-70919 IP Phone User Manual


 
NEAX2000 IVS
2
ISDN System Manual
Page 70 ND-70919 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
ISDN-PRI Programming
For originating calls to the ISDN, do the following programming:
DESCRIPTION DATA
Assign ISDN access code to each trunk
route assigned by CM30 YY=00.
NOTE: LCR can be used with ISDN-PRI.
Refer to Feature Programming
Manual.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access code
100-163: Trunk Route 00-63
Specify the timing start when making an
ISDN call from an attendant.
(1)
(2)
403
0 : Not available
1 : Available
Specify the timing start when making an
ISDN call from a Single Line Telephone
(PB/DP), D
term
or Attendant Console, if
required.
(1)
(2)
Y=0
50
03-14: 3 sec.-14 sec.
If no data is set, the timing start is not
effective.
Recommended setting is 05 (5 seconds).
NOTE: A # or timing start is used for outgoing ISDN calls when LCR is not invoked.
Example: 1-214-555-1212 is dialed from a D
term
. The PBX will access a bearer
channel and ship the digits only after the timing start timer has expired or # is dialed
by the caller. The # sign tells the PBX that dialing is completed.
CM08
CM41
CM20
E
F