NEC ND-70919 IP Phone User Manual


 
NEAX2000 IVS
2
ISDN System Manual
Page 142 ND-70919 (E), Issue 1.0
CHAPTER 4 CIRCUIT CARD INFORMATION
PN-CP14 (MP)
Switch Settings
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: Only when executing MP Program Download using the Software Activation Tool in
MATWorX Studio, set the SW3 to 5-8.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
card into/from its mounting slot.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
SW3 (Rotary SW)
NOTE 1
0-F
On Line
(Call processing is in progress)
2 Off Line (Call processing is stopped)
I/O port: As per CM40 YY=08
3 Off Line (Call processing is stopped)
I/O port: 9600 bps (Fixed)
5
NOTE 2
Off Line (Call processing is stopped)
I/O port: 9600 bps
6
NOTE 2
Off Line (Call processing is stopped)
I/O port: 19200 bps
7
NOTE 2
Off Line (Call processing is stopped)
I/O port: 38400 bps
8
NOTE 2
Off Line (Call processing is stopped)
I/O port: 57600 bps
B For clearing the office data
C For setting the resident system
program
1, 4, 9
A, D-F
Not used
(Continued)
0
0