NEC ND-70919 IP Phone User Manual


 
NEAX2000 IVS
2
ISDN System Manual
Page 120 ND-70919 (E), Issue 1.0
CHAPTER 3 SYSTEM DATA PROGRAMMING
Event Based CCIS Programming
DESCRIPTION DATA
Specify the number of digits to be received
on DID.
(1)
(2)
YY=09 Incoming Connection Signaling
00-63: B channel Trunk Route No.
08: ISDN Indial
NOTE 1
NOTE 1: This data should be assigned to
the B channel trunk route. For
D channel trunk route, no data
setting is required.
(1)
(2)
YY=16
Hooking Signal Sending to outside
00-63: B channel Trunk Route No.
0: Not sending
NOTE 1
(1)
(2)
YY=18 Digit conversion on DID call
00-63: B channel Trunk Route No.
0 : To provide
1 : Not provided
NOTE 1
(1)
(2)
YY=28 Outgoing Trunk Queuing
00-63: B channel Trunk Route No.
0: Restricted
NOTE 1
Determine trunk seizure sequence.
(1)
(2)
YY=83
00-63: B channel Trunk Route No.
0: As per CM08>078
NOTE 1
NOTE 2: This data should be assigned to
both B channel trunk route and
D channel trunk route.
(1)
(2)
YY=90
Assignment of BRT route for ISDN
00-63: B channel/D channel Trunk
Route No.
2: ISDN-Basic Rate Interface
NOTE 2
Select trunk seizure sequence. (1)
(2)
078
1 : Lowest available trunk
Assign the Number Conversion Block
number.
(1)
(2)
YY=00
X-XXXX: DID No.
000-999: Number Conversion Block
No.
CM35
B
CM08
CM76
C