AT&T System 85 Telephone User Manual


 
MDW 9000 Wireless Telephone
an ANN17B Hybrid pack in conjunction with a DS-1 carrier must be used to connect the switch
and the MDW 9000 terminal. On all other switches, including System 75, DEFINITY Generic 1
and Generic 3, a TN62B Hybrid pack must be used with the Universal carrier for this purpose.
Note: A DEFINITY Generic 2 may use either an ANN17B or a TN62B pack. In either case,
the latest vintage packs are recommended.
Button Numbering
Only the system manager should administer feature button assignments on the telephone. It is
recommended that you not use a feature that requires visuals (that is, the light next to each
administrable button) to be updated while the set is turned off, or any feature that may be
activated by button depression while the set is turned off (for example, Send All Calls).
Use Figure 4 for button numbering on the MDW 9000 set when it is connected to a System 75 or
DEFINITY Generic 1 or Generic 3 switch. Use Figure 5 for button numbering on the MDW 9000
set when it is connected to a System 85 or DEFINITY Generic 2 switch.
Note: On System 75 and DEFINITY Generic 1 and 3 switches, button numbering begins
with ‘‘1,’’ the button on the upper right of the display. On System 85 and DEFINITY
Generic 2, button numbering starts with ‘‘3.’’
ON
RANGE
P MUTE
MSG
BATT
321
54
DROP
10
FIGURE 3-29. Button Numbering for an MDW 9000 Connected to a System 75
or DEFINITY Generic 1 or 3
3-482