8110 and 8110M Telephones
Switch Administration
The 8110 and 8110M telephones must be administered in the following ways:
If the 8110 or 8110M telephone is connected to a System 75 or DEFINITY G1 or G3, it
must be administered as a 2500 analog telephone.
If the 8110 or 8110M telephone is connected to a System 85 or DEFINITY G2, it can be
administered as an analog line.
Note: The programmable dialing buttons are programmed individually on the telephone;
they are
not
administrable from the switch.
Administration of Hidden Features
For procedures on administering the hidden features on the 8110M (
to be done ONLY by the sys-
tem administrator
) such as
Reprogramming the Hold Feature
Administering the Timed Disconnect Feature
Locking the Programmable Dialing Buttons
refer to the
8102M and 8110M Telephones Quick Reference Guide
which comes in the box with
the 8110M.
Power Failure Operation
The 8110 or 8110M telephone can be used as an emergency station during power failure transfer
conditions. If the telephone is over 3,000 feet from the cabinet, the telephone will not work prop-
erly.
Ringer Equivalency Numbers
The Ringer Equivalency Number for the 8110 telephone is: 0.5A & 1.6B. For the 8110M tele-
phone the Ringer Equivalency Number is: 0.6A & 1.6B.
3-375