8101 Telephone
Distance Limitations
The maximum allowable distances of an 8101 telephone from the DEFINITY G1, G2, G3, System
75, or System 85 cabinet are shown in the table below.
NOMINAL MAXIMUM RANGE
IN FEET (METERS)
SYSTEM PORT BOARD
24 AWG 26 AWG
System 85 SN229 6,500 (1,981) 4,100 (1,246)
SN228B 6,500 (1,981) 4,100 (1,246)
DEFINITY G2 SN229 6,500 (1,981) 4,100 (1,246)
SN228B 6,500 (1,981) 4,100 (1,246)
TN742 15,200 (4,633) 10,000 (3,050)
TN746 3,000 (915) 2,000 (610)
DEFINITY G1 & G3 TN742 15,200 (4,633) 10,000 (3,050)
System 75 TN769 15,200 (4,633) 10,000 (3,050)
TN746 3,000 (915) 2,000 (610)
Power Requirements
The 8101 voice terminal receives power from the system and does not require any external
power supply.
Switch Administration
The 8101 telephone must be administered in the following ways:
If the 8101 telephone is connected to a System 75 or DEFINITY G1 or G3, it must be
administered as a 2500 analog telephone.
If the 8101 telephone is connected to a System 85 or DEFINITY G2, it can be admin-
istered as an analog line.
3-352