AT&T 2400 Cordless Telephone User Manual


 
Issue 2 December 1995 B-5
Using Metrics Mode
Using Metrics Mode
Use the following instructions to use the Metrics monitor mode.
1. Access the View menu as described in the previous section.
2. Press .
3. Press to select the Statistics option. You see the following screen:
This display updates occasionally, showing performance measurements for both
the SID’s call processing and message waiting activities. The top line shows a
running average for the number of calls serviced by the INTUITY System per
hour. The bottom line shows a similar statistic for the number of message waiting
commands serviced by the SID per hour. Use the Metric mode to monitor the
performance characteristics of your integrated system.
Clearing Statistical Information
The SID accumulates data that supports the Statistics and Metrics views. You
may wish to purge the data to begin taking new measurements, especially when
you add subscribers to the system, analog voice mail ports, or change your
usage habits. To clear the data, use the following instructions.
1. Log into security level 1. For instructions on logging in to the security level,
refer to Chapter , "NEAX 2400 Switch Administration", in this document.
2. Press at the VIEW action form.
3. Press to select Clear and remove the old statistics. After you press the
key, you see the following message on the screen:
The SID clears all statistical information. After a few seconds, the display clears
and the SID returns to the View menu.
METRICS Calls/Hr: 12001
MWIs/Hr: 9071
Clearing Statistics...
MODE
4
MODE
5