AT&T 2400 Cordless Telephone User Manual


 
Issue 2 December 1995 A-7
Error Logs
Table A-1. SID Error Codes and Descriptions
Code Description Type Action
1 VM Comm Error W Check SMDI connection and parameters
2 No Free VM_IN Packets W Check SMDI connection and parameters
3 Excess Data -- VM_IN Pkts W Check SMDI connection and parameters
5 Bad MWI Pkt W Check SMDI connection and parameters
6 No Free Centrex Pkts W Check SMDI connection and parameters
10 Excess Data - PBX_IN pkt W Check MCI connection and parameters
11 Kernel Error E
12 No Free PBX_OUT Packets W Check MCI connection and parameters
13 Idle Task Not Enough Time W
15 Bad PBX Pkts > 50% I Check MCI connection and parameters
16 Bad PBX Pkts > 5% I Check MCI connection and parameters
17 System Startup I No action required
19 System Powerdown I No action required
20 VM Comm Error > 5% E Check SMDI connection and parameters
21 VM Comm Error > 50% E Check SMDI connection and parameters
22 Boot Error: RTC E Set time and date
23 Boot Error: SCC E
24 Boot Error: LED E
25 Boot Error: Modem E
26 Boot Error: DPRAM E
27 Bad MWI Pkts > 50% I Check SMDI connection and parameters
28 Bad MWI Pkts > 5% I Check SMDI connection and parameters
29 PBX Comm Error > 5% E Check MCI connection and parameters
30 PBX Comm Error > 50% E Check MCI connection and parameters
31 Bad PBX Packet W Check MCI connection and parameters
32 Hardware Watchdog Reboot E
33 Integration Stop I No action required
34 Integration Start I No action required
35 No Free PBX_IN Packets W Check MCI connection and parameters
36 Hardware Reset I No action required
37 VM Remote Reset I No action required
38 Software Reset I No action required