NEC NDA-24311 Answering Machine User Manual


 
NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 99
Outgoing Trunk Queuing - PRI O-24
Service Conditions (cont’d)
11. OUTGOING TRUNK QUEUING is denied to a station line when the CALL BACK [C-1] or CALL
HOLD [C-6] feature is already activated.
12. CALL FORWARDING - INTERCEPT/ANNOUNCEMENT - ATTENDANT [A-1] cannot be used for a
call to a station that has activated OUTGOING TRUNK QUEUING.
13. If a user goes on-hook within 6 to 8 seconds after encountering all trunks busy, OUTGOING TRUNK
QUEUING can be set automatically to the station.
14. The station is set for OUTGOING TRUNK QUEUING for a maximum of 30 seconds to 1 hour. This time
is adjustable through the system database. After this time elapses, OUTGOING TRUNK QUEUING is
cancelled automatically.
15. ACCOUNT CODE [A-18] and FORCED ACCOUNT CODE [F-7] information can be recorded on
STATION MESSAGE DETAIL RECORDING (SMDR) [S-10] when used in conjunction with
OUTGOING TRUNK QUEUING.
Interactions
The stations setting the OUTGOING TRUNK QUEUING - PRI cannot activate the following services.
CALL BACK [C-1]
CALL WAITING - ORIGINATING [C-31]
CALL WAITING - TERMINATING [C-12]
CALL FORWARDING - INTERCEPT/ANNOUNCEMENT - ATTENDANT [C-75]