NEC NDA-24311 Answering Machine User Manual


 
NEAX2400 IPX ISDN Features and Specifications
Page 126
NDA-24311, Issue 1
S-88 SMDR for Data Call - RS232C - PRI
Service Conditions (cont’d)
11. The NEAX2400 IPX can accommodate up to two active ports or two redundant ports. Additional
hardware is required.
12. Supervision on the status of the external RS232C terminal is not performed.
13. Data rate output is 300, 600, 1200, 2400, 4800, and 9600 bps asynchronous ASCII (switch selectable).
14. A maximum of 28,000 simultaneous calls can be stored in the system memory (active calls). The call
record is sent to the output device and removed from memory upon completion.
15. Calls are allowed to complete if overflow active calls occur.
16. Local (intraswitched) data calls are not tracked. DATA CALL PEG COUNT [D-50] or DATA
TERMINAL TRAFFIC MEASUREMENT [D-21] can be used for local data traffic information.