NEC NDA-24311 Answering Machine User Manual


 
NEAX2400 IPX ISDN Features and Specifications
NDA-24311, Issue 1
Page 7
Automatic Circuit Assurance - PRI A-94
A-94 Automatic Circuit Assurance - PRI
General Description
When a call connection time is less or greater than a pre-determined time period, the NEAX2400 IPX can display
or print a reference to it using this feature.
Operating Procedure
No manual operation is required.
Service Conditions
1. This feature cannot be activated without STATION MESSAGE DETAIL RECORDING (SMDR) [S-10].
2. This feature is available for both incoming and outgoing calls.
3. This feature is not activated for station-to-station or station-to-Attendant calls under the following
conditions:
a.) When the station performs a switch hook flash
b.) When the station presses the D
term
line/feature key (HOLD, TRANSFER, or switch hook flash)
c.) When the Attendant presses HOLD key
d.) When the call is overridden by another call
e.) When the station answers Call Waiting or Attendant Camp-On call