Anritsu MT8852A Bluetooth Headset User Manual


 
Top-line Messages MT8850A / MT8852A Bluetooth Test Set
13000-000109 A-5
June 2003
LMP timeout (TC: xx
HOP: ON or OFF)
The MT8850A/MT8852A has sent an LMP test control to the
EUT and the EUT has not responded with an LMP accepted
message. “xx” represents the scenario number as defined in
the Bluetooth test mode specification. The following numbers
are used:
0: Pause Test Mode
3: Transmitter test – 1010 pattern
4: Transmitter test – PRBS9
5: Closed loop back – ACL packets
7: ACL packets without whitening
9: Transmitter test – 11110000 pattern
LMP timeout (test
pause)
The EUT has not sent an LMP accepted message to the Test
Pause message sent by the MT8850A/MT8852A.
Loop: current test failed The MT8850A/MT8852A is running a test or script in loop
mode with the "loop stop on fail" option ON. A measurement
has failed causing the test or script to stop running.
Max number of
connections
Maximum number of ACL connections.
Max number of SCO
conns
It is not possible to set up more than 3 SCO connections.
No packet detected Warning from the measurement processor. A request to
measure has been received and no packets have been
detected.
No payload detected The packets looped back by the EUT appear to have no
payload. The EUT may be looping back Null packets only.
No sync word correlation The MT8850A/MT8852A is unable to correlate to the EUT
transmitted packets header.
No test control End
event
The end of the test sequence has not been received.
Not enough
Measurements
The MT8850A/MT8852A did not receive sufficient measurable
packets to complete the selected test.
No connection made,
timeout
When attempting to establish a connection, the process failed
due to a timeout.
Operation not allowed When changing EUT audio settings, an ACL connection must
be established first.