Anritsu MT8852A Bluetooth Headset User Manual


 
Using the Script Menu MT8850A / MT8852A Bluetooth Test Set
Modulation Index Test (Single Payload Mode)
The MT8850A/MT8852A can perform this test using either loopback test controls or TX
test controls. The default form for this test is to use loopback. The following test is
described using the default test control.
The MT8850A/MT8852A transmits a packet that is looped back by the EUT. These
packets are the longest supported packet type as reported by the EUT during link set up
(DH1, DH3 or DH5) or the selected packet type.
When the test is performed in TX test mode, EUT transmitter and receiver frequencies
must be the same.
1. Refer to the settings below to enable the modulation index test in the test list.
Test control: TX or Loopback
Payload: 10101010 or 11110000
Packet type: Any
Hopping mode: Off
2. Choose “Modulation index” from the Script menu.
3. Press the
key to select or deselect this test from the script routine.
4. If a test is selected, the box will be filled in. If not selected the box will be hollow.
5. Press the
[Setup] soft key.
6. The Modulation index test limits screen displays.
7. Press the
[Defaults] soft key to restore the default values.
8. Choose the limit you want to change.
9. Press the
key and enter the new limit using the keypad.
10. Press the
[Enter] soft key.
11. Press the
key to return to the Script menu.
Maximum input power test (single payload mode)
The maximum input power test is not supported in single payload mode.
13000-000109 8-39
June 2003 Testing in Single Payload Script Mode