Issue 2 April 1996 7-5
Serial I/O Cards
DigiBoard Xem
Procedure 3:
Test the
installation
Start at the DigiWare Main Menu.
3 Fill in this screen according to your configuration. Our
suggested entries are:
Adapter Type: Digi_Xem_(ISA)
I/O Address: Dx204
Memory Address: 0x000D0000
TTY ID Select: Auto
Number of PORTS: 1
Config Status: Yes
4 Navigate through the screens until the Module
Configuration window displays.
5 Does the PORTS Module1 field equal PORTS 8em?
■ If yes, go to step 6.
■ If no, make sure your hardware is installed and the
cable between the ports card and the breakout box
is properly connected. Then go to step 6.
6 Follow the screen prompts until the configuration is
complete. Then go to Procedure 3: Test the installation.
Step Action
Step Action
1 Navigate through the screens until the Monitor - Digi
Port Authority window displays.