AT&T G3 Telephone User Manual


 
Issue 2 April 1996 7-5
Serial I/O Cards
DigiBoard Xem
Procedure 3:
Test the
installation
Start at the DigiWare Main Menu.
3 Fill in this screen according to your configuration. Our
suggested entries are:
Adapter Type: Digi_Xem_(ISA)
I/O Address: Dx204
Memory Address: 0x000D0000
TTY ID Select: Auto
Number of PORTS: 1
Config Status: Yes
4 Navigate through the screens until the Module
Configuration window displays.
5 Does the PORTS Module1 field equal PORTS 8em?
If yes, go to step 6.
If no, make sure your hardware is installed and the
cable between the ports card and the breakout box
is properly connected. Then go to step 6.
6 Follow the screen prompts until the configuration is
complete. Then go to Procedure 3: Test the installation.
Step Action
Step Action
1 Navigate through the screens until the Monitor - Digi
Port Authority window displays.