AT&T G3 Telephone User Manual


 
6-14 Issue 2 April 1996
Connectivity
To Program PBX Ports
Procedure 4:
Data-only
data module
and ADU
Use the following steps to program the following:
A stand-alone 7400B data module that only carries data
An ADU
You may have to use modem pooling.
See also For more details, refer to the DEFINITY G3 product
documentation. For a complete list of DEFINITY documents, see
Related Resources in the About This Book.
Step Action
1 Enter the following command:
add data-module
2 Enter the following in the Type field:
For a data module, enter pdm
For an ADU, enter data-line
3 Set the baud rate of the PBX or the AUDIX system to
match the baud rate of Proxy Agent.
4 For the ADU, set the Auto Adjust field to n.
End