When to use If you have a DEFINITY G3r, set the data module extensions on
the PBX after you have assigned a system port to an extension.
If you have a DEFINITY G3i with a netcon channel, you can skip
this procedure.
Procedure Use the following steps to set data module extensions.
Step Action
1 At the command prompt on the switch, execute the
following command:
add data-module xxxxx
xxxxx = the telephone number that you want to assign
to the data module that is hard-wired to the switch.
This data module accepts calls coming into the
switch.
Result: The Data Module screen displays.
2 Complete the Data Module screen.
Hint: We suggest that you use the screen’s defaults.
3 Do you want to establish a hotline connection to the
PBX?
If yes, go to step 4.
If no, go to step 6.