Panasonic KX-UTG200 Telephone User Manual


 
Default Value 32000
Web User Interface Reference Timer B (milliseconds) (Page 115)
SIP_TIMER_D
Value Format Integer
Description Specifies the value of SIP timer D (wait time for answer resending), in
milliseconds. For details, refer to RFC 3261.
Value Range 0, 250–64000
Default Value 5000
Web User Interface Reference Timer D (milliseconds) (Page 115)
SIP_TIMER_F
Value Format Integer
Description Specifies the value of SIP timer F (non-INVITE transaction timeout
timer), in milliseconds. For details, refer to RFC 3261.
Value Range 250–64000
Default Value 32000
Web User Interface Reference Timer F (milliseconds) (Page 116)
SIP_TIMER_H
Value Format Integer
Description Specifies the value of SIP timer H (wait time for ACK reception), in
milliseconds. For details, refer to RFC 3261.
Value Range 250–64000
Default Value 32000
Web User Interface Reference Timer H (milliseconds) (Page 116)
SIP_TIMER_J
Value Format Integer
Description Specifies the value of SIP timer J (wait time for non-INVITE request
resending), in milliseconds. For details, refer to RFC 3261.
Value Range 0, 250–64000
Default Value 5000
Web User Interface Reference Timer J (milliseconds) (Page 116)
312 Administrator Guide Document Version 2014-05
5.7.3 Per Line - SIP Settings