PERIODIC_INFORM_INTERVAL
Value Format Integer
Description Specifies the interval length, in seconds, when the CPE must attempt
to connect with the ACS and call the Inform method.
Note
This setting is available only when
"PERIODIC_INFORM_ENABLE" is set to "Y".
Value Range 30-2419200
Default Value 86400
CON_REQ_USER_ID
Value Format String
Description Specifies the username used to authenticate an ACS making a
Connection Request to the CPE.
Value Range Max. 63 characters (except ", &, ', :, <, >, and space)
Default Value Empty string
CON_REQ_PASS
Value Format String
Description Specifies the password used to authenticate an ACS making a
Connection Request to the CPE.
Value Range Max. 63 characters (except ", &, ', :, <, >, and space)
Default Value Empty string
5.3.8 SNMP Settings
SNMP_ENABLE
Value Format Boolean
Description Specifies whether to enable SNMP agent for remote management.
Value Range
Y (Enable SNMP)
N (Disable SNMP)
Default Value
N
Web User Interface Reference Enable SNMP (Page 177)