Panasonic KX-UTG200 Telephone User Manual


 
TIME_SYNC_INTVL
Value Format Integer
Description Specifies the interval, in seconds, to resynchronize after having
detected no reply from the NTP server.
Value Range 10–86400
Default Value 60
TIME_QUERY_INTVL
Value Format Integer
Description Specifies the interval, in seconds, between synchronizations with the
NTP server.
Value Range 10–86400
Default Value 43200
Web User Interface Reference Synchronization Interval (Page 105)
5.4.7 STUN Settings
STUN_SERV_ADDR
Value Format String
Description Specifies the IP address or FQDN of the STUN server.
Value Range Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value Empty string
Web User Interface Reference STUN Server Address (Page 98)
STUN_SERV_PORT
Value Format Integer
Description Specifies the port number of the STUN server.
Value Range 1–65535
Default Value 3478
Web User Interface Reference STUN Server Port (Page 99)
STUN_REFRESH_INTVL
Value Format Integer
Document Version 2014-05 Administrator Guide 251
5.4.7 STUN Settings