Panasonic KX-UTG200 Telephone User Manual


 
Description Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2…) separated by
commas.
Value Range 0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
Default Value 500
5.5.7 Flexible Button Settings
FLEX_BUTTON_FACILITY_ACT
Value Format Integer
Description Specifies a particular Facility Action for the flexible button. No facility
action will be taken for the button if the string is empty or invalid.
Value Range 0–2
0: Empty
1: ONETOUCH
2: BLF
Default Value 0
Web User Interface Reference Type (No. 1–24) (Page 142)
FLEX_BUTTON_FACILITY_ARG
Value Format String
Description Specifies the necessary values for the features assigned to flexible
buttons.
Value Range Max. 127 characters
Default Value Empty string
Web User Interface Reference Parameter (No. 1–24) (Page 143)
FLEX_BUTTON_LABEL
Value Format String
Description Specifies the message to be displayed on the screen when the flexible
button is pressed.
Value Range Max. 127 characters
Note
You can use Unicode characters for this setting.
Document Version 2014-05 Administrator Guide 275
5.5.7 Flexible Button Settings