KVH Industries FB500 Telephone Accessories User Manual


 
Chapter 5: Troubleshooting
Status signaling 175
55555
Troubleshooting
0800B PoE
Overvoltage
protection is
activated
Overvoltage is
detected in the
terminal. The
terminal will be
shut down in 10
minutes.
Do not use the
terminal.
Contact your
distributor.
0800D Antenna
Overvoltage
protection is
activated
Overvoltage is
detected in the
antenna. The
terminal will be
shut down in 10
minutes.
Do not use the
terminal.
Contact your
distributor.
08010 Undervoltage
has been
detected
The input voltage
has dropped below
an acceptable level.
The terminal will be
shut down in 10
seconds if the
situation persists.
Ensure a stable
power supply to the
terminal.
0801B Lost
connection to
the GPS
receiver
Communication
with the GPS
receiver in the
antenna is lost.
Contact your
distributor if the
warning persists.
0801D Uploading
firmware to
antenna
New firmware is
being uploaded to
the antenna.
The Event will be
cleared when
upload has finished.
Contact your
distributor if the
Event is not cleared
within 5 minutes.
ID Event Text Explanation Remedy
BGAN-X_UM.book Page 175 Wednesday, April 30, 2008 12:48 PM