Chapter 6: Settings
Decoded (Intermec ISCP)
180 WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual
6.25.3 Decoded (Intermec ISCP)
Tap on the Scanner dropdown menu, and choose Decoded (Intermec ISCP).
6.25.3.1 Options — Decoded (Intermec ISCP) Scanner
Laser On Time
The value assigned to this parameter determines how long the laser will remain on
when the scan button or trigger is pressed.
Double-tapping on this parameter displays a dialog box in which you can enter a
value between 1 and 10 seconds.
6.25.3.2 Advanced Options — Decoded (Intermec ISCP) Scanner
Continuous Scan Mode
Setting this parameter to ‘on’ keeps the laser on and continuously decoding as long
as the scanner button is pressed and held down.
Minimum Cancel Time
The value assigned to this parameter determines the time delay before the scanner is
turned off, once the scanner trigger or button is released. This gives the scanner a
minimum amount of time to complete its current decode before the scan is cancelled
when the user quickly triggers on/off.