Psion Teklogix 8100107B PDAs & Smartphones User Manual


 
Chapter 6: Settings
Decoded (Internal) Scanners
154 WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual
6.25.1.13 Codabar
Enabled
Set this parameter to on to enable “Codabar” or off to disable it.
Set Length L1 And Set Length L2
Lengths for “Codabar” can be set for Any length, Length within a range, One
discrete length or Two discrete lengths. The length of a code refers to the number of
characters (i.e., human readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a
selected length. Choosing Two discrete lengths allows you to decode only those
codes containing two selected lengths. Length within a range allows you to decode
a code type within a specified range from 5 to 55.
CLSI Editing
When enabled, this parameter strips the start and stop characters
and inserts a space after the first, fifth, and tenth characters of a 14-character
Codabar symbol.
Note: Symbol length does not include start and stop characters.
NOTIS Editing
When enabled, this parameter strips the start and stop characters from decoded
Codabar symbol.
Field Size/Char
Refer to page 148 for details.
6.25.1.14 MSI Plessey
Enabled
Set this parameter to on to enable “MSI Plessey”.