NEC ND-71762(E) Telephone User Manual


 
CHAPTER 6 ND-71762 (E)
Page 80
Issue 2
BASIC DATA ASSIGNMENT
STEP 3: ACIC1 - Allocate CSCG no. against the remote node in the network.
Assign the point code assigned in ADPCL in PC parameter and CSCG no. (even number) for basic route
assigned in ACSCL to CSCG parameter.
*CSCG no. for alternate route assignment is not necessary.
Example: PC=3, CSCG=2
STEP 4: ARNPL - Assign the access code for speech route (Logical Route)
*The assignment for signal route and dummy route is not necessary.
Example: LGRT=1, ACC=75
STEP 5: ARNP -Assign the self-office code to RT0 in the open numbering network.
This number is used for Calling number identification on SMDR, D
term
, DESK CONSOLE, ATTEN-
DANT CONSOLE, and inter-office services.
Example: RT=0, ACC=76