NEC ND-71762(E) Telephone User Manual


 
CHAPTER 8 ND-71762 (E)
Page 110
Issue 2
MAINTENANCE PROCEDURE
“13-K”: CCH Reset Interrupt Failure
(1) Meaning
The system message “13-K” indicates that a fault occurred to the PM (Port Microprocessor) within the CCH/
CCT circuit card and the restart processing is executed.
Note: This message is also displayed when the CCH/CCT circuit card has been reset.
(2) Related System Message
None
(3) Example of Printout
(4) Message Detail Data
(a) Accommodated location of the CCH detected the fault.
(Refer to paragraph 2.2.1)
SYSTEM MESSAGE 13-K [SUP] CCH RESET INTERRUPT FAILURE
NEC TOKYO MAY 14 10:30
LP00-0-ACT
1:
XX
00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
(a)
MG U G
MG:
U:
G:
Module Group
Unit
Group