Cisco Systems ATA 186 Telephone Accessories User Manual


 
5-20
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SCCP)
Ol-3141-01
Chapter 5 Parameters and Defaults
Optional Feature Parameters
RingCadence
Description
Use this parameter to specify the internal and external ringer cadence pattern, expressed as a triplet of
integers “a,b, and c”.
a—Number of seconds to turn the ring ON.
b—Number of seconds to turn the ring OFF.
c—The ring frequency, fixed at 25.
Value Type
List of three integer values, separated by commas
Range
1-65535
Default
2, 4, 25
Recommended Values:
United States —2,4,25
Sweden — 1,5,25
Voice Configuration Menu Access Code
929
Table 5-4 SigTimer Parameter Bit Definitions
Bit Number Definition
0-7 Call waiting period—The period between each burst of call-waiting tone.
Range: 0 to 255 in 0.1 seconds
Default: 100 (0x64=100 seconds)
8-15 Not used for SCCP.
16-25 Reserved—Should be set to 0.
26-27 Minimum hook flash time—The minimum on-hook time required for a hook flash event.
Range: 0 to 3
Default: 0 (60 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.
28-31 Maximum hook flash time—The maximum on-hook time allowed for a hook flash event.
Range: 0 to 15
Default: 0 (1000 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800
ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.