R5976214 VisuPlus Video Insertion Unit June 2003
6-7
6.5.4 VERBOSE
The VERBOSE command enables or disables the VISU
PLUS
from sending INFO messages.
Syntax:
VISU VERBOSE <VALUE> <CR>
VISU #Z <VALUE> <CR>
Arguments of VERBOSE:
Value Description
0 disable the VISU
PLUS
from sending INFO messages
1 enable the VISU
PLUS
to send INFO messages
Table 6-4
arguments of VERBOSE command
6.5.5 HW_SET_PARAM / HW_GET_PARAM
The HW_SET_PARAM command is used to configure hardware parameters. With the
HW_GET_PARAM command is it possible to retrieve a hardware parameter.
Syntax:
VISU HW_SET_PARAM <PARAMETER> <VALUE> <CR>
VISU #U <PARAMETER> <VALUE> <CR>
VISU HW_GET_PARAM <PARAMETER> <CR>
VISU #V <PARAMETER> <CR>
Parameters and correlated values:
Parameter Value Description
0 1..511 horizontal phase (Hphase)
1 1..255 vertical phase (Vphase)
2
0
1
enables / disables standalone mode:
VISU
PLUS
– EOS setup: synchronize VISU
PLUS
on external
Syncs
VISU
PLUS
standalone setup: synchronize VISU
PLUS
on inter-
nal generated Syncs
3 1..1023 line period for internal generated horizontal sync
calculation: 33*Requested LineTime (µ
µµ
µs);
only valid for VISU
PLUS
–standalone setup
4 1..63 horizontal sync width;
only valid for VISU
PLUS
–standalone setup
5 1..2047 internal total pixels per line (HTotalVisu)
calculation: (67*HTotalOutput)/PxlClk
where PxlClk is output pixelclock in MHz
6 1..2047 total lines per frame
24
1..1024
> 1024
horizontal resolution:
value remains the indicated value