Changing the Personality Module
If you change your PDA to another model, or if you inherit a 5230 IP Appliance from someone
with a different PDA model, you will probably need a new Personality Module before you
can use the your PDA with your 5230 IP Appliance. Talk to your Mitel Networks vendor to
find out which Personality Module you need for your PDA model.
To change a Personality Module
1. Unplug the LAN cable, the computer cable (if any) and the PDA charger cable at the
back of the 5230 IP Appliance (see the figure 5230 IP Appliance Connectors on
page 3).
2. Press downwards on the cradle latch (above model number), and remove the old
Personality Module.
3. Insert the new Personality Module in its recess, bottom first. Gently push the top of the
cradle in the recess, until the latch clicks in.
Inserting a Personality Module
4. Reconnect the LAN cable, computer cable (if any) and the PDA charger cable at the
back of the 5230 IP Appliance. You are now ready to use your PDA with the 5230 IP
Appliance.
Connecting a Local Power Supply
The 5230 IP Appliance supports both LAN powering (power supplied through the LAN
connection) and local powering of the set.
Your 5230 IP Appliance can be powered from any of the following sources:
Line Powering: a power source meeting the requirements of IEEE 802.3af for Power
Over LAN, as well as CAN/CSA C22.2 No. 60950-2000 3rd. Ed., UL 60950 3rd. Ed.,
and/or EN60950:2000 3rd. Ed. for Safety.
Local power supply: a Mitel Networks-supplied DC power adapter (see your Mitel
Vendor for part numbers).
Any other Mitel-recommended power source.
Note: Inserting a PDA in the wrong 5230 Personality Module may damage your PDA