Uniden EXP1240 Two-Way Radio User Manual


 
EXP1240 System Installation Guide Revision 06
© 2013 Uniden America Corp. PROPRIETARY AND CONFIDENTIAL Page 67 of 71
Parameter Description
SIP support for
multiple registrations
per account
Select
Enabled
to allow more than one handset to use the same
extension or SIP account; if this feature is not supported by the
SIP server, this field is disabled.
Table 29:
Base Station Group
parameters
Parameters Description
ID (chain)
Displays the ID number of the base stations in this chain, usually
corresponding to the order the base stations were added to the chain.
(The same ID number might be used in other chains.)
RPN (DECT
network)
Displays the Radio Part Number (DECT network ID) of the base stations
on this chain. The RPN is automatically assigned by the system, and it
must be unique on the local DECT network. (The same RPN might be
used at remote locations.)
MAC Address Displays the MAC address of each base station.
Version Displays the current firmware version on each base station.
Status
Connected
: The base station is connected and functioning properly.
Connection Loss
: The base station is not connected to the network.
This Unit
: The base station is the one you are currently logged into.
DECT Sync
source
Select the synchronization source for each base station on this
chain. The primary base station has its own RPN as the sync source.
The value in parentheses after the RPN shows the relative signal
strength of the other base stations in this chain.
DECT Property
Primary
: The designated base station serves as the primary
synchronization source for this chain.
Locked
: The base station is synchronized to its sync source.
Searching
: The base station is locating its sync source.
Free Running
: The base station was locked, but it has since lost its
synchronization source.
Unknown
: There is no current connection to the base station.