EXP1240 System Installation Guide Revision 06
© 2013 Uniden America Corp. PROPRIETARY AND CONFIDENTIAL Page 35 of 71
∘ The
IP Status field
of the base station you are logged into should show
This
unit
. Any other base stations in this chain should show
Connected
(i.e.,
connected to the network and functioning properly) as their IP status. If any
base station shows
Connection Loss
as its IP status, that base station is not
connected to the network or has lost power.
∘ The primary base station always serves as its own sync source, so the
DECT
sync source
field should display
Primary:RPN{its own RPN}.
The
DECT
Property
field shows
Primary
.
∘ This base station's
DECT sync source
will show
(any) RPN
and its
DECT
Property
field will show
Locked
.
∘ Check the
DECT sync source
drop-down box for this base station to verify
that there is a selection for the primary base station with a dBm value. If
there is not a dBm value, wait for the system to further synchronize
(approximately 2 minutes). When there is a dBm value, select the primary
base station from the
DECT sync source
drop-down box and click Save.
∘ If the primary base station is not on the list or if the signal strength is below -
70 to -73 dBm (-74dBm or less), move this base station to a different
location. (You could also configure the other Level 1 base stations first and
then come back and configure this one at Level 2.)
∘ The
DECT Chain
appears at the bottom of the display and shows the
synchronization source for all base stations in this system. Until the primary
base station is selected as the
DECT sync source
, there will be a warning in
the
DECT Chain
for this base station.
Figure 26:
Base Station Group
table, synchronization complete (
Multi-cell
screen)
13) When the system has finished synchronizing, repeat this process for each base station at
Level 1.