EXP1240 System Installation Guide Revision 06
© 2013 Uniden America Corp. PROPRIETARY AND CONFIDENTIAL Page 66 of 71
Parameter Description
Multi cell debug
Select:
–
Off –
To not include any multi cell logs in the syslogs. This is the
recommended setting unless requested otherwise by a
technician. A lot of logs are generated when the other
selections are chosen.
–
Data Sync
– To include in the syslogs logs regarding which
signals are received from which IP addresses. Timeout handling
and state changes are logged.
–
Auto tree
– To include in the syslogs logs regarding events
triggering the reconfiguration of the DECT chain, and timeouts
within Auto tree are logged.
–
Both
– To include both Data sync and Auto tree logs in the
syslogs.
Table 27:
DECT system settings
parameters
Parameter Description
DECT system RFPI
The radio network identity used by all base stations in a specific chain
to communicate with each other. (See Appendix B: RFPI Number on
page 71 for details.)
Auto configure
DECT sync source
tree
This setting should remain disabled.
Table 28:
Base station settings
parameters
Parameter Description
Number of SIP
accounts before
distributed load
Enter the maximum number of handset registrations (up to 30)
you want each base station in the chain to be able to handle. If
the number of registered handsets at a particular base station
goes beyond the number entered here, extra handsets will be
distributed to other base stations in this chain.