EXP1240 System Installation Guide Revision 06
© 2013 Uniden America Corp. PROPRIETARY AND CONFIDENTIAL Page 15 of 71
Initial System Configuration
This guide assumes that the EXP1240 system will be installed in a network environment
where the following servers are already installed and functioning:
• SIP server/VoIP PBX
• DHCP server
• NTP server
• TFTP server. This server must contain the following folders:
∘
LOG:
for SIP log files. Base stations must be able to write to this folder which
should be created in the TFTP server’s working directory.
∘
{firmware path}
: for firmware update files (see Setting Up Firmware Folders,
page 41)
• Syslog server. Base stations must be able to write to this server.
• DNS server Only required if you are using host names to access network nodes
There are some general server and base station requirements:
• The SIP server/VoIP PBX, NTP, and Syslog servers must be available at all times.
• If the base stations acquire their IP addresses dynamically (rather than being
statically assigned), then the DHCP server must be available at all times.
• The TFTP server must be available for firmware updates and SIP log uploads.
• All base stations must be on the same subnet.
• Servers can reside on the same machine.
Table 4 shows a top-level summary of the steps needed to configure the base station to
operate in a single-cell system. You will use these same steps to configure the first base
station in a multi-cell system.