Lucent Technologies 555-661-150 IP Phone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Network Reference
555-661-150
Issue 1
August 1998
Call-Handling Scenarios
Page 2-24Network Configuration Scenarios
2
Table 2–2. Scenario 1: Facilities Planning, Calls Originating within the private network and Going to the PSTN
* Local considerations may require a higher (more restrictive) FRL.
Component System A: New York, NY (Area Code: 212) System B: Holmdel, NJ (Area Code: 732)
DS1 Switch Type MERLIN LEGEND-PBX MERLIN LEGEND-Ntwk
ARS Access Code 99
Switch Identifiers
Programmed on
This System
22 for a system that is within 200 miles (System B) 21 for a system that is within 200 miles (System A)
Remote Access
Code and COR for
ARS Calls Routed
Via This System
Remote Access code: 889
All non-tie
Outward Unrestricted
Barrier Code Required (ignored for UDP extension
and non-local ARS calls)
Disallowed List 7
FRL=3*
Remote Access code: 122
All non-tie
Outward Unrestricted
Barrier Code Required (ignored for UDP extension
and non-local ARS calls)
Disallowed List 7
FRL=3*
Centralized
VMS/AA
Integrated VMI calling group extension: 771
VMI conversion number (non-local dial plan
member): 7999
UDP routing over route 01 or route 02, tandem PRI
trunks
FRL=0, voice
All dialed digits are absorbed and the digits 771 are
prepended.
Integrated VMI calling group extension: 771
Local dial plan members: extensions for ports used
to connect VMS/AA.
Message Waiting light updates for non-local
subscribers are sent over the tandem PRI signalling
D-channel