Lucent Technologies 555-661-150 IP Phone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Network Reference
555-661-150
Issue 1
August 1998
Call-Handling Scenarios
Page 2-48Network Configuration Scenarios
2
Table 2–8. UDP Extension Ranges: Scenario 2
System C Local Dial Plan: 4630–4699;
4850–4899; Remote Access Code: 889
Centralized VMS: 7771; Trunks 8001-8080
System D Local Dial Plan: 7340–7379; 7460-
7499; Remote Access Code: 326
Integrated VMI Calling Group for Routing
to Centralized VMS: 7771; Trunks 8801-
8880
Extension Range: 7340–7379
Pattern: 01
Route 01,
Pool=5810, T1-emulated tandem tie
FRL=3, Voice
Route 02
Pool=5950, PSTN facilities
FRL=6, Voice
Extension Range: 4630–4699
Pattern: 01
Route 01
Pool=6130, T1-emulated tandem tie
FRL=3, Voice
Route 02
Pool=6250, PSTN facilities
FRL=4, Voice
Extension Range: 7460–7499
Pattern: 02
Route 01
Pool=5816, T1-emulated tandem tie
FRL=3, Data
Extension Range: 4850–4899
Pattern: 02
Route 01
Pool=6136, T1-emulated tandem tie
FRL=3, Data
Extension Range: 326–326 (Remote Access)
Pattern: 03
Route 01
Pool=5810, T1-emulated tandem tie
FRL=6, Voice
Extension Range: 889–889 (Remote Access)
Pattern: 03
Route 01
Pool=6130, T1-emulated tandem tie
FRL=6, Voice
Extension Range: 6999–6999 (VMI conversion
number for routing to centralized VMS/AA;
assigned as single member of integrated VMI
calling group 7771)
Pattern: 04
Route 01
Pool=6130, T1-emulated tandem tie
FRL=0, Voice
All dialed digits are absorbed and the digits
7771 are prepended