Lucent Technologies 555-661-150 IP Phone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Network Reference
555-661-150
Issue 1
August 1998
Troubleshooting
Page 6-4Verifying Switch Identifiers
6
Verifying Switch Identifiers 6
For communications between switches to operate properly, the switch identifiers
must be properly set:
The switch identifier must be appropriate for a MERLIN LEGEND or
DEFINITY system.
The switch identifier must be appropriate for near or far distance between
connected systems.
The switch identifier must be programmed on every tandem trunk
If the switch identifiers are not properly set, any or all of the following problems
may occur:
Automatic cycling not blocked
ARS not working across systems (the switch can’t identify tandem versus
central office lines).
Incorrect call signaling information sent for calls to the VMS/AA (exact
results depend on the VMS used).
Incorrect SMDR reports
Message Waiting light updates not sent or received properly
Other unidentified problems
To check the switch identifier on a system, consult “Switch Identifiers” in Chapter 5
of this guide. Alternatively, follow one of the summary procedures listed below,
starting from the System Programming menu on your console or PC.
Console Procedure To check an identifier for one trunk:
/LQHV7UXQNVMore8'36Z1XP6LQJOHDial
trunk no.
(QWHUView switch no.([LW
([LW([LW([LW([LW
To check an identifier for a block of trunks:
/LQHV7UXQNVMore8'36Z1XP%ORFNDial
starting trunk in block
(QWHUDial ending trunk in
block
(QWHUView switch no. ([LW
([LW([LW
PC Procedure To check an identifier for one trunk:
Type trunk
no.
View switch no.
To view identifiers for a block of trunks:
Type starting trunk in
block
Type ending trunk in
block
View switch no.