Supported System Considerations 3
The following are considerations for voice messaging systems used for
centralized automated attendant on MERLIN LEGEND Communications System
Release 6.0 Version 11 and later systems.
MERLIN LEGEND System 3
For Release 6.1 and later systems, the number of dialed digits for the non-local
UDP range for a given pattern must be entered in a new system programming
screen (14.515). To access this screen, select
6\V5HQXPEHU.1RQ/RFDO8'3.Enter
first extension number in range.
;
.Enter last extension number in
range.
;
.Enter number of dialed digits for the range.
;
.
Intuity AUDIX 3
■ All local and non-local UDP stations must be administered on Intuity
AUDIX.
■ Within Intuity AUDIX, the parameter “transfer to subscribers only” must be
administered so as to ensure that Intuity AUDIX will deny transfers to all
but local and non-local UDP stations.
■ When optioned for MERLIN LEGEND systems, Intuity AUDIX can handle
3- or 4-digit dial plans (but not both simultaneously). For example, you
cannot have a 3-digit dial plan for one site and a 4-digit dial plan at another
site. Note that since a 5-digit dial plan is not supported by Intuity AUDIX
when optioned for MERLIN LEGEND systems, one of the work-arounds
described in Chapter 5 must be used to route calls to DEFINITY ECS or
DEFINITY ProLogix or the DEFINITY must have a 4-digit dial plan.
■ The MAP/5P platform supports 500 subscribers, the MAP/40 supports
3000 subscribers, and the MAP/100 supports 6000 subscribers.
■ Beginning with Intuity AUDIX R4, enhanced transfer security is available by
administering the allowed numbers list. Unless an extension (local and
non-local UDP) appears in this list, calls will not be transferred to that
number.
MERLIN LEGEND Mail 3
■ MERLIN LEGEND Mail should be set up with “Transfer to Subscriber-Only
Restrictions.”
■ For local UDP extensions, call answer mailboxes (up to 100) should be
used.
■ For non-local UDP numbers, transfer-only mailboxes should be used. The
maximum number of mailboxes of both types is 375.