Lucent Technologies 555-661-150 IP Phone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Network Reference
555-661-150
Issue 1
August 1998
Call-Handling Scenarios
Page 2-82Network Configuration Scenarios
2
Table 2–20. Scenario 4: Facilities Planning, Calls Originating within the Network and Going to the PSTN, Systems E and H
Component System E: Baltimore, MD (Area Code: 410) System H: Reston, VA (Area Code: 703)
DS1 Switch Type
MERLIN LEGEND-Ntwk MERLIN LEGEND-PBX
Switch Identifiers
Programmed on
This System
22 for a system within 200 miles (System H)
02 for a system more than 200 miles away (System F)
03 for a system more than 200 miles away (System G)
21 for a system within 200 miles (System E)
ARS Routing:
Calls to Local or
Nearby Area
Codes
All FRLs are set to low values for these calls. Four digits
are absorbed for 410 area code calls, and no digits are
absorbed for 301 and 703 area code calls.
The factory-set Special Numbers Table and Dial 0 Table
must use the main pool, which includes the system’s loop-
start line and directs emergency (911) and other special
numbers calls to the correct local services.
All other routes, including Toll Table, specify tandem trunk
pools with prepending of 9.
The default Local Table uses tandem trunks and prepends
91703.
Continued on next page