Cisco Systems 2.7 Wireless Office Headset User Manual


 
3-3
Installation and Configuration Guide for the CiscoWorks Wireless LAN Solution Engine
78-16345-01
Chapter 3 Installing WLSE 1130-19 Hardware
Installing the WLSE 1130-19 in a Rack
When installing and servicing the WLSE:
Disconnect all power and external cables before installing the system.
Install the system in compliance with your local and national electrical codes:
United States: National Fire Protection Association (NFPA) 70; United
States National Electrical Code.
Canada: Canadian Electrical Code, Part, I, CSA C22.1.
Other countries: If local and national electrical codes are not available,
see IEC 364, Part 1 through Part 7.
Do not work alone under potentially hazardous conditions.
Do not perform any action that creates a potential hazard to people or makes
the equipment unsafe.
Do not attempt to install the WLSE in a rack that has not been securely
anchored in place. Damage to the system and personal injury may result.
Due to the size and weight of the computer system, never attempt to install
the computer system by yourself.
See Precautions for Rack-Mounting, page 2-10 for additional safety information
on rack installation.
The server can be installed in a system 1U rack. The rack rail components are as
follows (numbers in parentheses refer to Figure 3-1):
2 telescopic rails (1, 2)
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the
top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting
or servicing the unit in the rack.
Statement 1006