B20. 9600 bps/4800 bps Modem Data Calls
Software version 4.0A (or later) allows for two simultaneous single
channel 4800 bps Air-Ground modem calls, or a single dual channel
9600 bps Air-Ground modem call.
To set up the station default modem call baud rate, start a Maintenance
Session. Press + (More) and then 5 (Modem). Press 1(4800
bps) or 2 (9600 bps) for desired setting.
B21. Modem Data Call Handoffs
(This is a System Function)
Software version 4.0A (or later) allows for 9600 bps/4800 bps data
call handoffs.
To enable data call handoffs, start a Maintenance Session, press +
(More) and then 5(Modem). Press 3to enable 4800 bps and/or
4to enable 9600 bps.
B22. Receiving Calls via a CDBR-2 PC Station
(This is a System Function)
Software version 4.0B (or later) allows for a CDBR-2 PC station to
receive uplink Ground-Air calls. The CDBR-2 station must be strapped
for PC and can be congured to receive Voice, Fax or TDD calls from
the ground through Remote Programming.
To congure, start a Remote Programming Maintenance Session
(Section VI, B18), press + (More) and then press 1 (Station Setup)
to view station settings. Uplink calls can be then congured by choos-
ing 3for Voice, 4 for Fax (Factory Default), or 5for TDD.
NOTE: For calls originating in the aircraft, the following dialing prefixes are valid
for a CDBR-2 PC station: “1” (Voice), “2” (Inplane), “3” (Fax), “4”
(Modem), “5” (TDD), and “
*