F. Baud Rate and Link Selection
Dialing Prefixes
The following dialing prex capabilities have been added as part
of software version 4.0A to facilitate the conguration of a specic
data/voice call. These prexes will override any congurations/factory
default values which were previously programmed.
F1. Baud Rate Selection Dialing Prefixes for Individual
Modem Calls
#4# Sets baud rate for call at 4800 bps
#9# Sets baud rate for call at 9600 bps (if both channels
are available)
NOTE: These prefixes override the station default baud rate (See Section VI, B20)
F2. Link Selection Dialing Prefixes for Individual Calls
#61# Selects Air-Ground (disables Auto Link Switch)
#62# Selects GroundCell (disables Auto Link Switch)
#63# Selects SATCOM (disables Auto Link Switch)
#612# Selects Air-Ground then GroundCell (SATCOM not included
in the rotation). Used with Genesys Airshow.
NOTE 1: These prefixes override the station default link (see Section VI, D1).
NOTE 2: Both Baud Rate and Link Selection prefixes can be utilized for the same
call (order sequence does not matter)
NOTE 3: The Link Selection prefixes can be used for all call types (i.e. Voice, Fax,
Modem and TDD).
8
(Rev. 8/04)
®