Error Messages
IPL Error Detection
While receiving data, IPL performs many checks on the data to ensure that the data is
received correctly. If an error is detected, IPL immediately aborts the download, and reports
the error on the terminal.
This screen displays until you press Enter. Once the screen is acknowledged, IPL returns
to the Main Menu screen to wait for a new selection.
The cause of the error displays under the Download Failed! indication. The errors that can
be reported, and the probable cause of the error, are as follows:
Error Description
Download Cancelled This error occurs when the user cancels the download.
Bad Checksum This error occurs when the file is invalid or there is a communication
error.
Bad Storage Checksum This error occurs when the file is invalid or there is a communication
error.
Not BIN File This error occurs when the file is invalid.
Not SREC File This error occurs when the file is invalid.
Record Short This error occurs when the file is corrupt or invalid.
Not SYMHEX File This error occurs when the file is invalid.
Bad HEX Record This error occurs when the file is invalid.
Invalid HEX Data This error occurs when the file is invalid.
Exceed Max Size The size of the image is also part of the Header record. If the data
to be written exceeds the size of the partition as indicated in the
partition table, this error occurs.
Invalid/Wrong Partition If a specific partition is selected from the partition list, and the
destination code of the Header record downloaded does not match
the index of that partition, this error occurs.