WLAN IP Telephony Manager 2245 installation
Screws – used to mount the WLAN IP Telephony Manager 2245 to the wall. Four 3/4-inch #8
panhead wood screws (or similar devices) are required.
CAT5 cable with an RJ-45 connector for the WLAN IP Telephony Manager 2245 – provides a
connection to the Ethernet switch.
DB-9 female null-modem cable – required for initial configuration of the WLAN IP
Telephony Manager 2245.
Pre-installation checklist
Ensure that the following requirements have been met prior to installation:
The location is adequate and power is available.
Access Points (APs) are SVP-compatible and coverage is adequate.
A dedicated line is available for remote modem access, if needed.
The telephone system administrator is on-site to program the existing telephone system.
Mounting the WLAN IP Telephony Manager 2245
The WLAN IP Telephony Manager 2245 can be mounted either vertically or horizontally.
The rack-mount kit is designed for mounting the WLAN IP Telephony Manager 2245 in a
standard 19-inch rack and contains the following equipment:
Mounting plates – two for each WLAN IP Telephony Manager 2245 to be mounted.
Screws – four rack-mount screws for each WLAN IP Telephony Manager 2245 to be mounted.
Wall-mounting the WLAN IP Telephony Manager 2245
1 Use a 1/8-inch drill bit to drill four pilot holes, on 1.84-inch by 12.1-inch centers
(approximately equivalent to 1 13/16-inch by 12 1/8-inch).
2 Insert the 3/4-inch #8 screws in the pilot holes and tighten, leaving a
1/8-inch to 1/4-inch gap from the wall.
3 Slide the WLAN IP Telephony Manager 2245 over the screws until the WLAN IP Telephony
Manager 2245 drops into place in the keyhole openings of the flange.
4 Tighten screws fully.
Note: The WLAN IP Telephony Manager 2245 requires a maximum distance of 325 feet
(100 meters) from the Ethernet switch.