BAUD – Baud Rate
This command selects/reports the baud rate of the serial port.
Command Form: DEVICE BAUD [Value]
Argument Type Size Values Units
Value Unsigned Integer 4 9600, 19200, 38400, 57600, 115200
(Null to query in text)
CALLDUR – Call Duration
This command returns current call duration. If no call is active, this command returns 0. At the time of call
termination, this command will automatically be sent out to report call duration. This command is read only.
Command Form: DEVICE CALLDUR <Channel> <Duration>
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Reserved 2 0
Duration String 8 String of format HR:MN:SS
CALLERID – Reports Caller ID Information
This command reports Caller Identification Information. This command is reportable only. It cannot be queried
or set.
Command Form: DEVICE CALLERID <Channel> <Number> <Argument>
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 17 (R)
Reserved Unsigned Integer 2 0
Number String 16 1 – 16 chars
Label String 16 1 – 16 chars
CGROUP – Compressor Group Select
This command selects/reports the setting of the compressor group.
Command Form: DEVICE CGROUP <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 5 (P)
Value Unsigned Integer 2 0 = none
1 – 4
(Null to query in text)
Compressor
Group
CHAIRO – Chairman Override Mode
This command selects/reports the setting of chairman override.
Command Form: DEVICE CHAIRO <Channel> [Value]
Argument Type Size Values Units
Channel Channel 1 See Groups and Channels
Group Group 1 3 (M)
Value Unsigned Integer 2 0 = Off
1 = On
2 = Toggle
(Null to query in text)